Search results for "Doppler Echocardiography"
showing 10 items of 39 documents
Accuracy of doppler echocardiography in measuring right-heart pressure in patients with pulmonary hypertension
2010
The assessment of pulmonary pressure is of great clinical importance not only for diagnostic purposes, but also for prognosis in patients with pulmonary arterial hypertension. The present study was undertaken on a consecutive basis with a group of patients who had had a previous diagnosis of pulmonary hypertension based on echocardiography, and were referred to our institute. The aim of this study was to determine how accurate Doppler echocardiography is in measuring right-heart pressures.
Early carotid atherosclerosis and cardiac diastolic abnormalities in hypertensive subjects
2004
Despite the fact that it is known that hypertension may be associated to early atherosclerosis manifestations, few data are to date available on the relationship between early carotid abnormalities and left ventricular diastolic dysfunction. To address this issue, 142 hypertensive patients (64 females and 78 males) younger than 55 years, at the first diagnosis of mild-to-moderate essential hypertension (WHO/ISH criteria), were selected from a database consisting of 3541 subjects referred to ultrasound cardiovascular laboratory in the last 5 years. Carotid intima-media thickness (IMT) was detected by high-resolution vascular ultrasound and left ventricular structure and function by the use o…
Mitral and aortic regurgitation in 84 patients with mucopolysaccharidoses
1995
In echocardiographic and necropsy studies nodular thickening of the mitral valve and, less frequently, of the aortic valve has been found in 60%-90% of patients with mucopolysaccharidoses (MPS). Little is known about the haemodynamic consequences of these morphological changes. In this study 84 unselected patients with different enzymatically proven MPS and 84 age and sex matched, healthy persons were studied prospectively by colour Doppler flow mapping. The patients' age ranged from 1 to 47 years (median 8.1 years). Mitral and aortic regurgitation were defined as a holosystolic or holodiastolic jet originating from the valve into the left atrium or the left ventricular outflow tract, respe…
Transitional hemodynamics in infants of diabetic mothers by targeted neonatal echocardiography, electrocardiography and peripheral flow study
2017
Objective: Metabolic alterations of intrauterine environment in diabetes mellitus (DM) lead to fetal cardiac dysfunctions that can persist after birth. The aim of the study was to assess the cardiovascular adaptation in infants born to diabetic mothers (IDM) with different degrees of glycometabolic control, in relation to revised guidelines for diagnosis of DM and quality improvements in neonatal care. Materials and methods: An observational case-control study was conducted on IDM with gestational, type 1 and type 2âDM. Relevant maternal and neonatal anamnestic, clinical and laboratory data were analyzed. Electrocardiographic and echocardiographic analyses, including structural and systo-…
Beta-adrenergic stimulation enhances left ventricular diastolic performance in normal subjects.
1997
To determine the effects of beta-adrenergic stimulation on transmitral Doppler echocardiography flow characteristics of left ventricular diastolic filling, we studied 10 healthy volunteers aged 23-31 years (mean age, 26.6 years) during intravenous infusion of isoprenaline in consecutive steps of 0.1, 0.2, 0.4, 0.75, and 1.5 micrograms/min (each for 15 min). Saline control infusion was given in the same manner in a crossover and blinded protocol. Compared with the infusion of placebo, stepwise increasing doses of isoprenaline caused a dose-related increase in early and late diastolic filling velocities and velocity-time integrals, a lengthening of the acceleration time, and a shortening of t…
Evaluation of diastolic function by the Tissue doppler in children affected by non- compaction
2007
The Tissue doppler analysis is a new echocardiographic approach to evaluate the diastolic function. In this report we performed a Tissue doppler analysis in a series of 15 children affected by non-compaction. The bidimensional echo-cardiogram showed a systolic function which was reduced only in 8 patients. Alterations of the diastolic function were founded in 7 patients: in 2 cases, a reduction of the E tissue wave was present in all segments. In 3 patients the diastolic dysfunction was limited to apical and lateral segments. In the last 2 children a reduction of the E wave interested only the apical segments. There was a strong correlation between systolic and diastolic dysfunction: in fac…
Usefulness of abdominal ultrasonography in the analysis of endoscopic activity in patients with Crohn's disease: changes following treatment with imm…
2013
The objective of this study was to analyze the accuracy of abdominal ultrasonography (AUS) in the assessment of mucosal healing in patients with Crohn's disease (CD) receiving immunomodulators and/or biological treatment, with ileocolonoscopy as the reference standard.Thirty patients were included in a prospective longitudinal study. All patients underwent ileocolonoscopy and AUS before and after a minimum of one year of treatment. The Crohn's Disease Endoscopic Inflammatory Index of Severity (CDEIS) was used for endoscopic assessment whereas AUS was analyzed by means of bowel wall thickness, color Doppler grade and percentage of increase of parietal enhancement after contrast injection.In …
Contrast-enhanced ultrasonography: usefulness in the assessment of postoperative recurrence of Crohn's disease.
2013
Abstract Aim The aim of this study was to assess whether the contrast-enhanced ultrasonography (CEUS) can increase the value of the ultrasonography in the study of postoperative recurrence of Crohn's disease (CD). Materials and methods 60 patients with CD who had previously undergone ileocolic resection underwent prospectively both CEUS and colonoscopy within a 3-day period. The sonographic examination included evaluation of bowel wall thickness, transmural complications, colour Doppler grade and contrast-enhanced US. In addition a sonographic score was established. The capacity of CEUS to diagnose endoscopic recurrence, as well as its severity, was assessed by calculating the sensitivity, …
Ambulatory follow-up of aortic dissection by transesophageal two-dimensional and color-coded Doppler echocardiography.
1989
Follow-up of 18 patients with aortic dissection (five with type I, one with type II, 11 with type III dissection according to DeBakey) by transesophageal, two-dimensional and color-coded Doppler echocardiography showed a persistence of the false lumen in five of seven patients (71%) after surgery and in nine of 11 patients (82%) after medical therapy. In two patients treated with surgery, the dissected part of the aorta had been resected, whereas in two patients treated medically, a progressive and complete obliteration of the false lumen was observed. In the false lumen, thrombus formation was absent in four, localized in four, and progressive in six patients. Flow within the false lumen c…
Quantification of mitral valve stenosis by three-dimensional transesophageal echocardiography
1996
The aim of this study was the evaluation of the diagnostic potentials of transesophageal 3D- echocardiography in the determination of mitral valve stenosis. 54 patients were investigated by transthoracic and multiplane transesophageal echocardiography. In 41 patients cardiac catheterization was performed. 3D- echocardiographic data acquisition was performed by automatic transducer rotation at 2 degree increments over a span of 180 degrees. The transesophageal probe was linked to an ultrasound unit and to a 3D- workstation capable of ECG- and respiration gated data acquisition, postprocessing and 2D/3D image reconstruction. The mitral valve was visualized in sequential cross-sectional planes…